no-load running check valve

no-load running check valve

Nominal diameter: DN50 ~ 250mm
Nominal pressure: PN20MPa
Operating temperature: ≤160℃
Design and manufacture: ASME B16.34, JB/T3595, E101
Pressure temperature: ANSI B1 6.34, JB/T74, JB/T3595, E101
Structure length: ANSI B16.10, E101, GB/T15188.1, JB/T2766
Butt welding connection size: ASME B16.25, GB/T12224, E101
Inspection and test: ISO5208, GB/T13927, JB/T3595

Product overview

The empty discharge check valve is installed on the outlet pipe of the high pressure feed pump of the thermal power unit to prevent water backflow and protect the feed pump. The valve works with the small flow automatic recirculation side valve of the water pump. When the feed water pump is under low load or the outlet closure door is closed, the automatic recirculation bypass valve should be in the open position to ensure the safe operation of the water pump. When the air discharge check valve is opened, the recirculation bypass valve automatically closes. It is not suitable for media containing solid particles and large viscosity.

Product characteristics
1. The valve works with the recycling bypass valve to maintain the safe operation of the system.
2. When the main valve disc moves up and down and the medium flows back, the channel is closed under the action of the medium pressure and the spring.
3, the valve disc seal is made of stainless steel surfacing welding, wear resistance, abrasion resistance, reliable sealing.
4, the valve should be installed vertically.


Main size  

DN

L

D

D1

D2

D6

b

Z-d

f

f2

H

weight(kg)

100

430

360

292

245

138

66

8-41

3

6

630

285

150

550

440

360

305

190

82

12-Ф48

3

6

650

510

175

610

475

3944

340

214

84

12-Ф48

3

6

685

700

225

900

580

483

418

268

100

12-Ф58

3

6

765

1105

250

900

670

572

508

319

110

16-Ф58

3

6

780

1330