Flame retardant - explosion-proof pipe flame arrester

Flame retardant - explosion-proof pipe flame arrester

Product model: GZW-I
Nominal pressure: PN1.0 ~6.4MPa
Nominal diameter: DN25 ~ DN600mm
Connection mode: flange, welding, thread
Applicable temperature: -20℃ ~ +440℃
Manufacturing material: A105,304,316,316L
Applicable media: air, natural gas, liquefied gas and other non-corrosive or weakly corrosive gas medi
Product overview
GZW-I,GYW-I type flame-proof - explosion-proof pipeline flame arrester, using a special fire retardant net with 3 to 13 mesh combination structure. Prevents 13 subsonic flame passes. Effectively ensure the safety of pipeline system. Widely used in: petrochemical, boiler, gas purification, coal mine gas emission and other occasions. In order to meet the requirements of different working conditions, our company produced this product is divided into flange pipe common type and welding high pressure pipe special type two. The main body can be made of cast steel or stainless steel 304, 316L material. It has the characteristics of reasonable structure, light weight, corrosion resistance, safe and reliable use, qualified explosion resistance, etc.



Main feature

Gzw-i type deflagration pipe arrester is a new type of combustible gas pipe arrester, which is a new product.
The flame arrester was tested jointly by the University of Science and Technology of China and the Tianjin Fire Science Research Institute of the Ministry of Public Security, and its performance fully conforms to the provisions of GB13347-92 "Fire arrester performance and test method for oil Gas pipeline flame arrester". The flame arrester structure is reasonable, and the fire retardant layer is made of stainless steel material, which is corrosion-resistant and easy to clean. The shell is made of stainless steel, carbon steel and cast steel, which can meet the needs of different process pipelines.



Main use

1, conveying flammable gas on the pipeline.
2. Torch system.
3. Oil and gas recovery system.
4, heating furnace fuel gas pipe network.
5, gas purification Tonghua system.
6. Gas analysis system.
7. Coal mine gas emission system. 1. The flame arrester has been tested at subsonic speed for 13 consecutive times, which can prevent the flame from passing each time.
8, water pressure test 2.4MPa without leakage.



Main shape and flange connection dimensions


  • Model


Weight
( Kg/台)

PN
(MPa)


  • Dimensions
(mm)



  • Screw


K

D

DL

L

Quantity

Thread

GZW-20

DN20

1.6

75

105

195

200

4

M12

GZW-25

DN25

85

115

195

200

4

M12

GZW-40

DN40

110

150

245

240

4

M16

GZW-50

DN50

125

165

245

240

4

M16

GZW-80

DN80

160

200

280

250

8

M16

GZW-100

DN100

180

220

335

260

8

M16

GZW-150

DN150

240

285

460

360

8

M20

GZW-200

DN200

295

340

520

420

12

M20

GZW-250

DN250

355

405

580

430

12

M24

GZW-300

DN300

410

460

705

450

12

M24

GZW-600

DN600

770

840

1120

580

20

M33